This guide will help you to get familiar with Modbus connector configuration for ThingsBoard IoT Gateway.
Use general configuration to enable this connector.
We will describe connector configuration file below.
{
"server": {
"type": "tcp",
"host": "127.0.0.1",
"port": 5020,
"timeout": 35,
"method": "socket",
"byteOrder": "BIG",
"devices": [
{
"unitId": 1,
"deviceName": "Temp Sensor",
"attributesPollPeriod": 5000,
"timeseriesPollPeriod": 5000,
"sendDataOnlyOnChange": true,
"attributes": [
{
"tag": "string_read",
"type": "string",
"functionCode": 4,
"objectsCount": 4,
"address": 1
},
{
"tag": "bits_read",
"type": "bits",
"functionCode": 4,
"objectsCount": 1,
"address": 5
},
{
"tag": "8int_read",
"type": "8int",
"functionCode": 4,
"objectsCount": 1,
"address": 6
},
{
"tag": "16int_read",
"type": "16int",
"functionCode": 4,
"objectsCount": 1,
"address": 7
},
{
"tag": "32int_read_divider",
"type": "32int",
"functionCode": 4,
"objectsCount": 2,
"address": 8,
"divider": 10
},
{
"tag": "8int_read_multiplier",
"type": "8int",
"functionCode": 4,
"objectsCount": 1,
"address": 10,
"multiplier": 10
},
{
"tag": "32int_read",
"type": "32int",
"functionCode": 4,
"objectsCount": 2,
"address": 11
},
{
"tag": "64int_read",
"type": "64int",
"functionCode": 4,
"objectsCount": 4,
"address": 13
}
],
"timeseries": [
{
"tag": "8uint_read",
"type": "8uint",
"functionCode": 4,
"objectsCount": 1,
"address": 17
},
{
"tag": "16uint_read",
"type": "16uint",
"functionCode": 4,
"objectsCount": 2,
"address": 18
},
{
"tag": "32uint_read",
"type": "32uint",
"functionCode": 4,
"objectsCount": 4,
"address": 20
},
{
"tag": "64uint_read",
"type": "64uint",
"functionCode": 4,
"objectsCount": 1,
"address": 24
},
{
"tag": "16float_read",
"type": "16float",
"functionCode": 4,
"objectsCount": 1,
"address": 25
},
{
"tag": "32float_read",
"type": "32float",
"functionCode": 4,
"objectsCount": 2,
"address": 26
},
{
"tag": "64float_read",
"type": "64float",
"functionCode": 4,
"objectsCount": 4,
"address": 28
}
],
"attributeUpdates": [
{
"tag": "shared_attribute_write",
"type": "32int",
"functionCode": 6,
"objectsCount": 2,
"address": 29
}
],
"rpc": [
{
"tag": "setValue",
"type": "bits",
"functionCode": 5,
"objectsCount": 1,
"address": 31
},
{
"tag": "getValue",
"type": "bits",
"functionCode": 1,
"objectsCount": 1,
"address": 31
},
{
"tag": "setCPUFanSpeed",
"type": "32int",
"functionCode": 16,
"objectsCount": 2,
"address": 33
},
{
"tag":"getCPULoad",
"type": "32int",
"functionCode": 4,
"objectsCount": 2,
"address": 35
}
]
}
]
}
}
In order to connect to Modbus server, the one must set required parameters of section “server”. Due to the nature of preferred way of communication with Modbus server there are 2 options how to configure this part: if using TCP/UDP or via Serial port.
There are 2 variants of server section:
|
|
This sub-section provides array of configurations for devices.
This configuration contains common connection parameters and settings for data processing. Available parameters are as follows:
Parameter | Default value | Description |
---|---|---|
unitId | 1 | Id of current device on Modbus. |
deviceName | Temp Sensor | Name of the current device |
attributesPollPeriod | 5000 | Period in milliseconds for check the attributes on device. |
timeseriesPollPeriod | 5000 | Period in milliseconds for check the telemetry on device. |
sendDataOnlyOnChange | true | Sending only if data changed from last check, if no – data will send after every check |
Example:
"devices": [
{
"unitId": 1,
"deviceName": "Temp Sensor",
"attributesPollPeriod": 5000,
"timeseriesPollPeriod": 5000,
"sendDataOnlyOnChange": true,
Configuration in this unit provides settings for processing data on Modbus server, which will be interpreted in ThingsBoard platform instance as attribute of device.
Parameter | Default value | Description |
---|---|---|
tag | test | Tag, which will use as attribute key for ThingsBoard platform instance. |
type | 32int | Type of value. Available data types |
functionCode | 4 | Function to use in processing data. Modbus functions |
objectsCount | 1 | Count of objects to read. |
address | 1 | Object address to check. |
Optional parameters:
multiplier - result of reading will be multiplied by value of this parameter.
divider - result of reading will be divided by value of this parameter.
Example:
"attributes": [
{
"tag": "test",
"type": "32int",
"functionCode": 4,
"objectsCount": 1,
"address": 1
}
],
Configuration in this unit provides settings for processing data on Modbus server, which will be interpreted in ThingsBoard platform instance as telemetry of device.
Parameter | Default value | Description |
---|---|---|
tag | test | Tag, which will use as attribute key for ThingsBoard platform instance. |
type | 16uint | Type of value. Available data types |
functionCode | 4 | Function to use in processing data. Modbus functions |
objectsCount | 1 | Count of objects to read. |
address | 1 | Object address to check. |
Example:
"timeseries": [
{
"tag": "test",
"type": "16uint",
"functionCode": 4,
"objectsCount": 1,
"address": 1
}
],
Configuration in this unit provides settings for Attribute update requests from ThingsBoard platform instance.
Parameter | Default value | Description |
---|---|---|
tag | shared_attribute_write | Shared attribute name. |
type | 32int | Type of value. Available data types |
functionCode | 6 | Function to use in processing data. Modbus functions |
objectsCount | 2 | Count of objects to write. |
address | 1 | Object address. |
Example:
"attributeUpdates": [
{
"tag": "shared_attribute_write",
"type": "32int",
"functionCode": 6,
"objectsCount": 2,
"address": 1
}
],
Configuration in this unit provides settings for RPC requests from ThingsBoard platform instance to device.
Parameter | Default value | Description |
---|---|---|
tag | setValue | RPC method name. |
type | bits | Type of value. Available data types |
functionCode | 5 | Function to use in processing data. Modbus functions |
objectsCount | 1 | Count of objects to write. |
address | 1 | Object address. |
Example:
"rpc": [
{
"tag": "setValue",
"type": "bits",
"functionCode": 5,
"objectsCount": 1,
"address": 1
}
],
Additional information about Modbus functions and supported data types.
The Modbus connector supports the following Modbus functions:
Modbus function code | Description |
Read data | |
1 | Read Coils |
2 | Read Discrete Inputs |
3 | Read Multiple Holding Registers |
4 | Read Input Registers |
Write data: | |
5 | Write Coil |
6 | Write Register |
15 | Write Coils |
16 | Write Registers |
A list and description of the supported data types for reading/writing data.
Type | Function code | Objects count | Note |
---|---|---|---|
string | 3-4 | 1-… | Read bytes from registers and decode it (‘UTF-8’ coding). |
bytes | 3-4 | 1-… | Read bytes from registers. |
bits | 1-4 | 1-… | Read coils. If objects count 1 - result will be interpret as a boolean, else the result will be an array with bits. |
16int | 3-4 | 1 | Integer 16 bit. |
16uint | 3-4 | 1 | Unsigned integer 16 bit. |
16float | 3-4 | 1 | Float 16 bit. |
32int | 3-4 | 2 | Integer 32 bit. |
32uint | 3-4 | 2 | Unsigned integer 32 bit. |
32float | 3-4 | 2 | Float 32 bit. |
64int | 3-4 | 4 | Integer 64 bit. |
64uint | 3-4 | 4 | Unsigned integer 64 bit. |
64float | 3-4 | 4 | Float 64 bit. |